Juniper EX4300 Hardware Manual page 109

Hide thumbs Also See for EX4300:
Table of Contents

Advertisement

Table 57: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device
Altitude
EX9208
No performance
degradation up to
10,000 feet (3048
meters)
EX9214
No performance
degradation up to
10,000 feet (3048
meters)
XRE200
No performance
degradation up to
10,000 feet (3048
meters)
Related
Documentation
Copyright © 2015, Juniper Networks, Inc.
Relative Humidity
Normal operation ensured in
relative humidity range of
5% through 90%
(noncondensing)
Normal operation ensured in
relative humidity range of
5% through 90%
(noncondensing)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
NOTE:
Install EX Series switches only in restricted areas, such as dedicated
equipment rooms and equipment closets, in accordance with Articles 110–16,
110–17, and 110–18 of the National Electrical Code, ANSI/NFPA 70.
Clearance Requirements for Airflow and Hardware Maintenance for EX2200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3300 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4300 Switches
on page 93
Clearance Requirements for Airflow and Hardware Maintenance for an EX4600 Switch
Clearance Requirements for Airflow and Hardware Maintenance for an EX Series
Redundant Power System
Clearance Requirements for Airflow and Hardware Maintenance for EX4500 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4550 Switches
Clearance Requirements for Airflow and Hardware Maintenance for an EX6210 Switch
Clearance Requirements for Airflow and Hardware Maintenance for an EX8208 Switch
Chapter 6: Preparation Overview
Temperature
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operation ensured in the
temperature range 41° F through
104° F (5° C through 40° C)
Seismic
Complies with Zone 4
earthquake
requirements as per
GR-63.
Complies with Zone 4
earthquake
requirements as per
GR-63.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
87

Advertisement

Table of Contents
loading

Table of Contents