List Of Error Codes - Panasonic LB-DH8 series Operator's Manual

Data archiver
Table of Contents

Advertisement

Others

List of error codes

Email
Code
notification
E1000
±
E1010
±
E1020
E1021
±
E1022
E1023
±
E1030
E1040
±
E1060
±
E1070
±
E2000
E2001
±
E2002
E2003
E2004
E2010
E2011
±
E2012
E2013
Errors and warnings
SNMP trap
notification
A fault has been detected in flash memory in the unit or the
±
peripheral circuit.
It needs to be repaired.
The internal temperature of the unit is high.
)Check if the exhaust port of the fan at the rear of the unit is being
clogged with an obstacle, and if yes, remove the obstacle.
)Check the log records to determine if the regular fan or the
redundant fan has a fault, and if yes, it needs to be repaired.
±
If the problem persists, please contact your support service
provider. ( 138)
)The fan works when the unit starts up or the unit requires cooling
during operation.
Abnormalities have been detected in the SAS/iSCSI/FC interface
board or the peripheral circuits of the interface.
±
It needs to be repaired.
The type of I/F card connected to each module is different.
±
It needs to be repaired.
An error has been detected during the software processing in the
unit.
±
)Turn off and on the unit, and try again.
If it still does not operate, it needs to be repaired.
Failed to turn on the Extension module.
±
It needs to be repaired.
The number of modules could not be found properly due to a
±
malfunction of the extension microcomputer circuit board.
It needs to be repaired.
Self-diagnosis has detected an error in the changer mechanism in
the changer unit or the peripheral circuit of the changer mechanism.
It needs to be repaired.
±
An error has been detected in the changer mechanism in the
changer unit or the peripheral circuit of the changer mechanism.
It needs to be repaired.
±
130