Press [Model]
3
Make any detailed settings as required for the position compensation processing.
Refer to Detailed Settings for Search Position Compensation, below.
4
Press [OK].
5
Press [Back].
• Detailed Settings for Search Position Compensation
The settings for the Search Position Compensation item are almost the same as those for the Search
inspection item. Only the [Multi-point output] setting of the Search item is not included in the settings of the
Search Position Compensation item. Make the settings for teaching and the judgement conditions in the same
way as for the Search item. (
Also, the following settings are included only in the Search Position Compensation Item.
• Source Image
You can select the image to which to apply the results of position compensation processing.
Applying the Results of Position Compensation: p. 76
• Interpolation
You can select the precision of position compensation.
If you select [Bilinear], the precision of position compensation will increase.
[Image] − [Image adjustment] − [Search position comp.] − [Modify] − [Details] −
[Scroll parameter] − [Interpolation]
The settings are the same as those for the Shape Search Position Compensation item.
Interpolation: p. 78
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Expression text string
JG
Judgement
DX
Scroll X
DY
Scroll Y
X
Position X
Y
Position Y
SX
Reference X
SY
Reference Y
CR
Correlation
80
Adjusting the Images That Were Taken
[Search position comp.]
4-8 Inspecting with the Search Inspection Item: p. 137)
Data name
This is the judgement result.
This is the amount of position com-
pensation for the X coordinate.
This is the amount of position com-
pensation for the Y coordinate.
This is the X coordinate of the position
where the model was found.
This is the Y coordinate of the position
where the model was found.
This is the X coordinate of the position
where the model was registered.
This is the Y coordinate of the position
where the model was registered.
This is the correlation.
Description
−2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
0 to 100
Data range
FQ2-S4 User's Manual