Shape Search Ii - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

External
Category Data name
refer-
ence
number
1000+N
Mea-
Sub-region correlation
(N=0 to
sure-
N
99)
ment
result
1100+N
Sub-region density
(N=0 to
deviation N
99)

Shape Search II

External
Category Data name
refer-
ence
number
0
Mea-
Judgement
sure-
ment
result
5
Correlation
6
Position X
7
Position Y
8
Angle
9
Reference X
10
Reference Y
11
Reference angle
12
Detection coordinate X Acquisition
13
Detection coordinate Y Acquisition
14
Count
103
Output
Reflect
parame-
ter
120
Model
Rotation
region
121
Rotation angle upper
limit
122
Rotation angle lower
limit
FQ2-S4 User's Manual
Setting/Acqui-
Data range
sition
Acquisition
0 to 100
only
Acquisition
Sub-region density devia-
only
tion N
Setting/Acqui-
Data range
sition
−2: No judgement (not
Acquisition
only
measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not per-
formed error,
−14: Figure not registered
error,
−15: Out of range error
Acquisition
0 to 100
only
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
−180 to 180
Acquisition
only
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
−180 to 180
Acquisition
only
−99,999.9999 to
only
99,999.9999
−99,999.9999 to
only
99,999.9999
Acquisition
0 to 32
only
Setting/Acqui-
0: Yes, 1: No
sition
Setting/Acqui-
0: No, 1: Yes
sition
−180 to 180
Setting/Acqui-
sition
−180 to 180
Setting/Acqui-
sition
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
0
CRN
---
0
DVN
---
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
−2
JG
Logged data
0
CR[0] to
Logged data
CR[31]
0
X[0] to
Logged data
X[31]
0
Y[0] to
Logged data
Y[31]
0
TH[0] to
Logged data
TH[31]
0
SX
---
0
SY
---
0
ST
---
0
RX
---
0
RY
---
0
C
Logged data
0
---
---
0
---
---
180
---
---
−180
---
---
External Reference Parameters