Measurement Data That Can Be Logged (Bar Code); Errors - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Measurement Data That Can Be Logged (Bar Code)

The following values can be logged as measurement data.
Measured item
Range of value
−2: No judgement (not measured),
Judgement
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error,
−16: Measurement timeout error
Num. of characters
0 to 1024
* When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 252

Errors

Errors in Teaching
A teaching error message is displayed If bar codes cannot be read during an automatic registration.
The reading may be unstable due to low contrast.Adjust the brightness to improve the contrast of the bar code.
Adjusting the Brightness: p. 61
FQ2-S4 User's Manual
Description
This is the judgement result from the measurements.
The number of characters read is output.