Sensitive Search

External
Category Data name
refer-
ence
number
0
Mea-
Judgement
sure-
ment
result
5
Correlation
6
Deviation
7
Measurement position
X (search center posi-
tion)
8
Measurement position
Y (search center posi-
tion)
9
Angle
10
Detection X
11
Detection Y
12
Reference position X
13
Reference position Y
14
Reference angle
15
NG sub-region
16
Sub-region number
17
Sub-region number (X) Acquisition
18
Sub-region number (Y) Acquisition
19
Measurement position
X (sub-region)
20
Measurement position
Y (sub-region)
103
Output
Reflect
parame-
ter
532
External Reference Parameters
Setting/Acqui-
Data range
sition
−2: No judgement (not
Acquisition
only
measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not per-
formed error,
−14: Figure not registered
error,
−15: Out of range error
Acquisition
0 to 100
only
Acquisition
Color Camera: 0.000 to
only
219.9705
Monochrome Camera:
0.000 to 127.000
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
−180 to 180
Acquisition
only
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
−180 to 180
Acquisition
only
Acquisition
0 to 100
only
Acquisition
0 to 99
only
0 to 9
only
0 to 9
only
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
Setting/Acqui-
0: Yes, 1: No
sition
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
−2
JG
Logged data
0
CR
Logged data
0
DV
Logged data
0
X
Logged data
0
Y
Logged data
0
TH
Logged data
0
RX
Logged data
0
RY
Logged data
0
SX
Logged data
0
SY
Logged data
0
ST
Logged data
0
CT
Logged data
0
AN
Logged data
0
ANX
Logged data
0
ANY
Logged data
0
DX
Logged data
0
DY
Logged data
0
---
---
FQ2-S4 User's Manual