● Settings in the FQ2 (Device Parameter Settings)
1
Right-click the FQ2 in the network on the Network Configurator and select [Parameter] − [Edit].
2
The Edit Device Parameters Dialog Box will be displayed. Make the required settings.
Parameter name
*1
001 Input Size
*2
002 Output Size
*3
003 RPI
*1
Although the data size can be set as high as 502 bytes, with the current version set one of the following as the total data size for the output
area (data output size) and the response area (16 bytes).
• 48 bytes (default)
• 80 bytes
• 144 bytes
• 272 bytes
*2
Although the data size can be set as high as 502 bytes, with the current version use the default setting of 20 bytes.
*3
The packet interval (RPI) is set in the connection settings between the PLC and the Sensor. No setting is required here.
FQ2-S4 User's Manual
Value
The total size of response area and output
area
The data size of command area
The requested packet interval
Outputting Data and Controlling Operation through EtherNet/IP
Setting range
48 to 272
20
10000