Omron FQ2-S4 User Manual page 444

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Setting the Inspection Item Data: 280F 00501020
This command sets the parameters and measurement values of the specified inspection item.
● Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● End Codes
End code (hex)
0000
FFFF
● Parameter Descriptions
Inspection item number
External reference num-
ber
Setting
442
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
Vision Sensor command code
(4 bytes)
00501020
MRES
SRES
(1 byte)
(1 byte)
End code
Meaning
Command execution ended normally.
Command execution ended in an error.
Specifies the number of the inspection item to set.
Specifies the external reference number.
12-2 External Reference Parameters: p. 491
Specifies the set value.
12-2 External Reference Parameters: p. 491
Inspection item number (4 bytes) External reference
Inspection item number from 00
to 1F (2 digits max.)
Vision Sensor command code
(4 bytes)
00501020
Set value (4 bytes)
number (4 bytes)
External reference
Set value (1,000
number
times the actual
value)
FQ2-S4 User's Manual

Advertisement

Table of Contents
loading

Table of Contents