Menu command
Description
Sets the area to write execution results
from the Sensor.
Control outputs, command codes,
response codes, and response data
Set the first address of the response
area.
Sets the area to write output data from
measurements.
Output data 0 to 31
Set the first address of the output area .
Output hand-
Sets whether to establish an interlock
shake
with the PLC when data is output.
Retry details
Enables or disables retrying communica-
tions.
This can be set only when the communi-
cations type is set to a PLC Link.
Retry interval
Sets the interval for retrying communica-
tions.
This setting is enabled only when [Retry
details] is set to [ON].
This can be set only when the communi-
cations type is set to a PLC Link.
Max output data Sets the upper limit of the number of out-
put data to use for PLC Link outputs.
Any output data that is beyond this value
is discarded.
This can be set only when the communi-
cations type is set to a PLC Link.
Output data size Sets the data size to output for EtherNet/
IP output.
If the data size that is set is exceeded,
data will be output in more than one
transfer.
This can be set only when the communi-
cations type is set to EtherNet/IP.
Connection
Sets the TPC connection mode.
mode
Refreshing task
Set the communications cycle for cyclic
period
tag data link communications for the
Vision Sensor.
This can be set only when the communi-
cations type is set to EtherNet/IP.
Timeout
Sets the timeout time when handshaking
is enabled.
This can be set only when the communi-
cations type is set to EtherNet/IP.
FQ2-S4 User's Manual
Setting range
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default), Work Area
(WR), Holding Bit Area (HR), Auxiliary
Bit Area (AR), DM Area (DM), EM Area
(EM0 to EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
0 to 99999 (default: 100)
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0)
EM Area (EM1)
:
EM Area (EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
0 to 99999 (default: 200)
No (default) or Yes
ON or OFF (default)
0 to 2,147,483,647 ms (default:10,000
ms)
32 to 1024 (default: 256)
32 bytes (default), 64 bytes, 128 bytes, or
256 bytes
TCP server (default) or TCP client
1 to 10,000 ms (default:10 ms)
0.1 to 120.0 s (default: 10 s)
Data
Refer-
ence
System
p. 376
System
System
p. 376
System
System
p. 376
System
p. 376
System
p. 376
System
p. 376
System
p. 336
System
System
p. 336
System
p. 337
485