A - Specifications

Supplemental Characteristics

Table A-2 lists the supplemental characteristics, which are not warranted but are descriptions of typical
performance determined either by design or type testing.
Parameter
Output Programming
Range
Average Programming
Resolution
OVP Accuracy
Average Current
Measurement Resolution
Maximum Current
Measurement
Sink Current
Programming Accuracy
Temperature Coefficient
(change/C°)
Readback Accuracy
Temperature Coefficient
(change/C°)
2
Drift
Remote Sense Capability
(voltage per load lead)
Output Voltage Rise Time
Output Voltage Fall Time
Output Voltage Settling
5
Time
Dynamic Measurement
6
System
1
The sink current decreases linearly from 2.8A @ 0 V to 1.2 A @ 15 V. Sink current does not track the programmed current.
2
Following a 30 minute warm-up, the change in output over 8 hours, under constant ambient, load and line conditions.
3
Add 2 mV to the load regulation for each 1 V change in the positive output lead.
4
Add 3 mV to the load regulation for each 1 V change in the negative output lead.
5
To settle within 1 LSB or 3.75mV of the final value for Output 1.
6
For a pulse waveform, the accuracy of any individual data point in the buffer is dependent on the rise time of the pulse. For a
current pulse of 1.4A with a rise time constant of 50µs, the error in measurement of a single data point during the pulse rise time
is typically 10mA.
144
Table A-2. Supplemental Characteristics
Agilent 66111A
Voltage:
Current:
OVP:
Voltage:
Current:
OVP:
High Range:
Low Range:
Voltage:
Current:
OVP:
0.01% + 300 µV
Voltage:
Current (dc):
Current (acdc):
Current (low range):
Voltage:
Current: +
10% to 90%:
90% to 10%:
0 to rated voltage:
rated voltage to 0:
Buffer Length:
Sample Rate Range:
66311B/D,
Agilent 66309B/D
output 1 only
0 – 15.535 V
0 – 3.0712 A
22 V
3.75 mV
0.75 mA
100 mV
2.4 % + 240 mV
3.5 mA
NA
7 A
- 2 A @ 7.5 V
0.01% + 0.5 mV
0.01% + 15 µA
0.015% + 4 mV
0.01% + 300 µV
0.02% + 15 µA
0.02% + 15 µA
0.05% + 120 µA
NA
0.01% + 0.3 µA
NA
0.01% + 1 mV
0.01% + 30 µA
3
up to 4 V
< 200 µs
< 200 µs
0.5 ms
1 ms
0 − 4096 points
NA
15.6µs − 31200s
Agilent
Agilent
66309B/D
output 2 only
0 – 12.25 V
0 – 1.52 A
NA
14 mV
1.75 mA
NA
NA
213 µA
55 µA
0.6 µA
NA
1.8A
1
- 0.03 A @ 7.5 V
0.03% + 1.5 mV
0.03% + 0.4 mA
NA
0.02% + 1.5 mV
0.02% + 0.4 mA
NA
NA
0.03% + 3 mV
0.03% + 0.8 mA
up to 4 V
< 200 µs
< 35 ms
NA
NA
NA
4