Supplemental Characteristics

Parameter
Temperature Coefficient (for 12 months)
Output Voltage Overshoot
(during turn- on or turn- off AC power state
with the output control set to less than 1 V)
Voltage Programming Speed, to within 1% of
total excursion
Up
Down
Last Memory Setting Enabled
Over Voltage Protection Response Time
Parameter
Over Voltage Protection Accuracy
± (% of output + offset)
Over Voltage Protection Programmable
Range
Over Current Protection Accuracy
± (% of output + offset)
Over Current Protection Programmable
Range
U8001A/U8002A User's and Service Guide
Table 4-2 Supplemental Characteristics
Full Load
No Load
Full Load
No Load
<1.5 ms when the trip voltage is equal or greater than 3 V and <10 ms
when the trip voltage is less than 3 V (average time for output to drop
from 90% of output voltage to 1 V after OVP condition occured)
Table 4-3 Protection Features
Specifications and Characteristics
U8001A
CV: <100 ppm/ °C
CC: <380 ppm/ °C
150 ms
100 ms
30 ms
450 ms
U8001A
<0.5% +0.5 V
1 V to 33 V
<0.5% +0.5 A
1 A to 3.3 A
U8002A
CC: <300 ppm/ °C
<1 V
Yes
U8002A
1 A to 5.5 A
4