5 – Front Panel Operation

Output Control Keys

Output control keys control the output functions of the dc source.
Voltage
Press this key to access the voltage menu.
Display
1
VOLT <value>
2
VOLT <value>
Current
Press this key to access the current menu.
Display
1
CURR <value>
2
CURR <value>
Shift
Res
Not available
Output
Press this key to access the output menu list.
Display
*RST
COUPLING <char>
TYPE:CAP <char>
PON:STATE <char>
PROT:DLY <value>
RI <char>
DFI <char>
DFI:SOUR <char>
PORT <char>
DIGIO <char>
SENSE:PROT<char>
1
REL:MODE <char>
Protect
Press this key to display protection status.
Display
OVER CURRENT
NO FAULT
Shift
OV
Press this key to access the overvoltage protection menu.
Display
PROT:STAT <char>
PROT:LEV <value>
Shift
Cal
This key accesses the calibration menu (Refer to Appendix B for details).
1
Notes:
only valid for Agilent 66309B/D units with firmware revision A.02.04 and up
2
These parameters are stored in non-volatile system memory
3
These status summary bits are explained in chapter 7
4
These parameters are stored in non-volatile state memory
value = a numeric value
char = a character string parameter
p
Use
È
Use
Æ
Use
54
Command Function
Sets the voltage of output 1 (the main output of all models)
Sets the voltage of output 2
Command Function
Sets the current of output 1 (the main output of all models)
Sets the current of output 2
Command Function
Places the dc source in the factory-default state
Couples or decouples output 1 and output 2 (NONE or ALL)
Sets the output compensation (HIGH | H2 | LOW)
Select the power-on state command (RST | RCL0)
Sets the output protection delay in seconds
Sets the remote inhibit mode (LATCHING | LIVE | OFF)
Sets the discrete fault indicator state (ON | OFF)
Selects the DFI source (QUES | OPER | ESB | RQS | OFF)
Sets the output port functions (RIDFI or DIGIO)
Sets and reads the I/O port value (0 through 7)
Enables or disables the open sense lead detect circuit (ON | OFF)
Sets the relay mode for Option 521units (DD, HD, DH, or HH)
(applies to both outputs; output 1 shown)
Command Function
Status of the protection features (example shows overcurrent)
Status of the protection features (example shows none tripped)
Command Function
Enables or disables overvoltage protection (ON | OFF)
Sets the overvoltage protection level
q
and
to scroll through the menu commands.
É
and
to scroll through the menu parameters.
Ç
and
to select a digit in a numeric entry field.
1
1
2
2
2
1
2
3