Supplemental Characteristics - Agilent Technologies E3633A User Manual

Dc power supplies
Hide thumbs Also See for E3633A:
Table of Contents

Advertisement

Chapter 8 Specifications

Supplemental Characteristics

Supplemental Characteristics
Table 1-2.
Supplemental Characteristics
Parameter
Output Programming Range
(maximum programmable values)
Voltage Programming
Speed: Maximum time required
for output voltage to settle within
1% of its total excursion (for
resistive load). Excludes
command processing time.
Remote Sensing Capability
Voltage drop
Up to 0.7 V per each lead
Load regulation
Add 5 mV to spec for each 1-volt change in the + output
lead due to load current changes.
Load voltage
Subtract voltage drop in load leads from specified output
voltage rating.
Temperature Coefficient, ±(% of output + offset)
Maximum change in output/readback per °C after a 30-minute warm-up
Voltage
0.01% + 3 mV
Current
0.02% + 3 mA
Stability, ±(% of output + offset)
Following a 30-minute warm-up, with the output in the ON state according to the
operating mode (CC with load or CV), and with a change in the output over 8 hours
under constant load, line, and ambient temperature.
Voltage
0.02% + 1 mV
Current
0.1% + 1 mA
Agilent E3633A
Low Range
0 to +8.24 V/
0 to 20.6 A
High Range
0 to +20.6 V/
0 to 10.3 A
OVP
1 V to 22 V
OCP
0 A to 22 A
Full Load No Load Full Load No Load
Up
95 msec
45 msec
Down
30 msec
450 msec 30 msec
Agilent E3634A
0 to +25.75 V/
0 to 7.21 A
0 to +51.5V/
0 to 4.12 A
1 V to 55 V
0 A to 7.5 A
80 msec
100 msec
450 msec
8