8 – Language Dictionary
CALibrate:SAVE
This command saves any new calibration constants after a calibration procedure has been completed in
nonvolatile memory. If CALibrate:STATe OFF is programmed without a CALibrate:SAVE, the previous
calibration constants are restored..
Command Syntax CALibrate:SAVE
Parameters None
Examples CAL:SAVE
Related Commands CAL:PASS
CALibrate:STATe
This command enables and disables calibration mode. The calibration mode must be enabled before the
dc source will accept any other calibration commands.
The first parameter specifies the enabled or disabled state. The second parameter is the password. A
password is required if the calibration mode is being enabled and the existing password is not 0. If the
password is not entered or is incorrect, an error is generated and the calibration mode remains disabled.
The query statement returns only the state, not the password.
NOTE:
Whenever the calibration state is changed from enabled to disabled, any new calibration
constants are lost unless they have been stored with CALibrate:SAVE.
Command Syntax CALibrate:STATe<bool>[,<NRf>]
Parameters 0 | 1 | OFF | ON [,<password>]
*RST Value OFF
Examples CAL:STAT 1,6812
Query Syntax CALibrate:STATe?
Returned Parameters <NR1>
Related Commands CAL:PASS
CALibrate:VOLTage
This command initiates the calibration of the output voltage and the voltage readback circuit.
Command Syntax CALibrate:VOLTage[:DC]
Parameters None
Examples CAL:VOLT
CALibrate:VOLTage2
Agilent 66309B/D only
This command initiates the voltage calibration of output 2.
Command Syntax CALibrate:VOLTage2
Parameters None
Examples CAL:VOLT2
CALibrate:VOLTage:PROTection
This command calibrates the overvoltage protection (OV) circuit. The dc source automatically performs
the overvoltage calibration, which takes several seconds to complete.
Command Syntax CALibrate:VOLTage:PROTection
Parameters None
Examples CAL:VOLT:PROT
102
CAL:STAT
CAL:STAT OFF
CAL:SAVE
*RST
CAL:VOLT:DC