Front Panel Menus - At A Glance - Agilent Technologies 66111A User Manual

Fast transient dc source/mobile communications dc source
Table of Contents

Advertisement

Front Panel Menus - At a Glance

Address
ADDRESS 7
ó
INTF GPIB
ó
BAUDRATE 300
ó
PARITY NONE
ó
FLOW NONE
ó
LANG SCPI
ó
REMOTE FP OFF
ó
ROM: A.00.00
ó
SN: US12345678
*RCL 0
Recall
*SAV 0
Shift
Save
ERROR 0
Shift
Error
2
5.000V 0.104A
Channel
Shift
1
12.000V
Meter
ó
1
12.500V MAX
ó
1
1.000V MIN
ó
1
12.330V HIGH
ó
1
0.080V LOW
ó
1
12.000V RMS
ó
1
0.350A MAX
ó
1
0.050A MIN
ó
1
0.400A HIGH
ó
1
0.012A LOW
ó
1
0.210A RMS
ó
1
12.000V DC:DVM
ó
1
12.000V RMS:DVM
1
VOLT 12.000
Voltage
2
VOLT 2.000
1
CURR 2.000
Current
2
CURR 1.000
Shift
Res
OVERCURRENT
Protect
*RST
Output
ó
COUPLING ALL
ó
TYPE:CAP LOW
ó
PON:STATE RST
ó
PROT:DLY 0.08
ó
RI LATCHING
ó
DFI OFF
ó
DFI:SOUR OFF
ó
PORT RIDFI
ó
DIGIO 7
ó
SENSE:PROT OFF
ó
1
REL:MODE DD
VOLT:PROT 22
Shift
OV
ó
PROT:STAT ON
CURR:RANG HIGH
Shift
Input
ó
CURR:DET ACDC
ó
TINT 46.8
ó
POINT 2048
CAL ON
Shift
Cal
É
È
Use
and
to select parameters (table shows factory defaults).
1
Not valid for Agilent Model 66309B
3
Only valid for Agilent Model 66309B/D
Sets the GPIB Address
Selects an interface (GPIB | RS232)
Selects baud rate (300 | 600 | 1200 | 2400 | 4800 | 9600)
Selects message parity (NONE | EVEN | ODD | MARK | SPACE)
Selects flow control (XON-XOFF | RTS-CTS | DTR-DSR | NONE)
Selects language (SCPI | COMP)
Enables or disables Agilent 14575A remote front panel (ON | OFF)
Displays the firmware revision of the instrument
Displays the serial number of the instrument
Recalls the instrument state
Saves the present instrument state
Displays the number of errors in the SCPI error queue
Toggles the display between output 1 and output 2 (output 2 shown)
1
0.204A
Measures the output voltage and current (output 1 shown)
Measures the peak output voltage
Measures the minimum output voltage
Measures the high level of a voltage pulse waveform
Measures the low level of a voltage pulse waveform
Measures the rms voltage
Measures the peak output current
Measures the minimum output current
Measures the high level of a current pulse waveform
Measures the low level of a current pulse waveform
Measures the rms current
Measures the dc voltage on the DVM input
Measures the rms voltage on the DVM input
Sets the voltage of output 1 on all models
Sets the voltage of output 2
Sets the current limit of output 1 on all models
Sets the current limit of output 2
Not available
Protection status (example shows overcurrent tripped)
Places the dc source in the factory-default state
Couples or decouples output 1 and output 2 (NONE or ALL)
Sets the output capacitance compensation (HIGH, H2, or LOW)
Select the power-on state command (RST or RCL0)
Sets the output protection delay in seconds
Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
Sets the discrete fault indicator state (ON or OFF)
Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
Sets the output port functions (RIDFI or DIGIO)
Sets and reads the I/O port value (0 through 7)
Enables or disables the open sense lead detect circuit (ON or OFF)
Sets the relay mode for Option 521 units (DD, HD, DH, or HH) (output 1 shown)
Sets the overvoltage protection level
Enables or disables overvoltage protection (ON or OFF)
Sets the current range (HIGH, LOW, or AUTO)
Sets the current measurement detector (ACDC or DC)
Sets the time interval for a front panel measurement in seconds
Sets the buffer size for a front panel measurement
Accesses calibration menu (See Appendix B).
2
Not valid for Agilent Model 66111A
4
Only valid for Agilent Model 66311D/66309D
1
1
2
2
2
2
2
2
2
2
3
3
4
4
2
Use
to exit any menu.
Meter
Quick Reference - 1
1
1
1
2
2
3
2
19