Area (Fq2-S1/S2/S3 Series Or Fq2-S4 Series Only) - Omron FQ2-S Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

External
Category Data name
refer-
ence
number
138
Judge-
Width upper limit
ment
condi-
139
Width lower limit
tions
140
Mea-
Edge enhancement
sure-
level
ment
141
Color to count
condi-
tions
142
Mode
310
Logging
Data logging switch for
condi-
entire unit
tions
311
Data logging switch for
judgement
312
Data logging switch
for edge pitch
313
Data logging switch
for average pitch
314
Data logging switch
for maximum pitch
315
Data logging switch
for minimum pitch
316
Data logging switch
for average width
317
Data logging switch
for maximum width
318
Data logging switch
for minimum width
700
Display
Edge pitch display
settings
701
Average pitch display
702
Pitch display
703
Average width display
704
Width display

Area (FQ2-S1/S2/S3 series or FQ2-S4 series only)

External
Category Data name
reference
number
0
Mea-
Judgement
sure-
ment
result
FQ2-S/CH User's Manual
Setting/Acqui-
Data range
sition
Setting/Acqui-
0 to 99,999.9999
sition
Setting/Acqui-
0 to 99,999.9999
sition
Setting/Acqui-
0 to 442
sition
Setting/Acqui-
(Monochrome Cameras)
sition
0: White, 1: Black
Setting/Acqui-
(Monochrome Cameras)
sition
0: Standard, 1: Precise
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Data logging OFF,
sition
1: Data logging ON
Setting/Acqui-
0: Display, 1: Do not display
sition
Setting/Acqui-
0: Display, 1: Do not display
sition
Setting/Acqui-
0: Display, 1: Do not display
sition
Setting/Acqui-
0: Display, 1: Do not display
sition
Setting/Acqui-
0: Display, 1: Do not display
sition
Setting/Acqui-
Data range
sition
−2: No judgement (not mea-
Acquisition
only
sured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed
error,
−14: Figure not registered error,
−15: Out of range error
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
99,999.9
---
Judgement
999
condition
0
---
Judgement
condition
100
---
---
0
---
---
0
---
---
1
---
---
1
---
---
1
---
---
1
---
---
1
---
---
1
---
---
1
---
---
1
---
---
1
---
---
0
---
---
0
---
---
0
---
---
0
---
---
0
---
---
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
−2
JG
---
External Reference Parameters
383

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch seriesFq2-s/ch series

Table of Contents