Measurement Data That Can Be Used For External Outputs And Calculations; Measurement Data That Can Be Logged For Edge Pitch - Omron FQ2-S Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Measurement Data That Can Be Used for External Outputs and Calculations

The following values can be output to external devices or used in calculations as measurement data.
Expression text string
JG
N
P
PH
PL
W
WH
WL
4-17 Calculations and Judgements Using Inspection Item Data: p. 213

Measurement Data That Can Be Logged for Edge Pitch

The following values can be logged as measurement data.
Measured item
Judgement
Edge pitch
Average pitch
Max. pitch
Min. pitch
Average width
Max. width
Min. width
*
When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 269
190
Inspecting with the Edge Pitch Inspection Item
Data name
Judgement
This is the judgement result.
Edge pitch
This is the number of objects.
Average pitch
This is the average pitch.
Max. pitch
This is the maximum pitch.
Min. pitch
This is the minimum pitch.
Average width
This is the average width between
edges.
Max. width
This is the maximum width between
edges.
Min. width
This is the minimum width between
edges.
Range of value
−2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error
0 to 999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
Description
Description
This is the judgement result from the measurements.
This is the number of objects that were detected.
This is the average pitch that was detected.
This is the maximum pitch that was detected.
This is the minimum pitch that was detected.
This is the average width that was detected between edges.
This is the maximum width that was detected between edges.
This is the minimum width that was detected between edges.
Data range
−2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error
0 to 999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999