Adjusting Judgement Parameters During Operation; Preparations; Changing The Judgement Parameters In Run Mode - Omron FQ2-S Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

6-4 Adjusting Judgement Parameters during Operation

FQ2-S1
FQ2-S2
This Sensor enables judgement parameters to be adjusted while measurements are being performed.
Downtime can be eliminated with this feature because the production line does not have to be stopped while
making adjustments.

Preparations

This function is switched OFF as a default to prevent it from inadvertently working during operation.
Turn ON the function if you want to use it.
(Setup Mode) − [Sensor settings] − [Adjustment mode in Run]
1
Press [ON].

Changing the Judgement Parameters in Run Mode

This section describes how to change the judgement parameters without stopping measurement in Run Mode.
Run Mode
1
Select the inspection item or position compensation
item for which you want to adjust the judgement pa-
rameters using the
2
Press [
] – [Adjust judgement].
3
Press the parameters and change the values of the
judgment conditions for them with the slider.
4
Press [OK].
The judgement results with the changed judgement
parameters will appear.
Important
The changed judgement parameters will not be reflected in the measurement result until [OK] is pressed.
246
Adjusting Judgement Parameters during Operation
FQ2-S3
FQ2-S4
FQ2-CH
and
Buttons.
FQ2-S/CH User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch seriesFq2-s/ch series