Failure to Read Characters

Failure to Read Characters during Teaching
• The read results may be unstable if the contrast is low. Adjust the brightness to improve the contrast.
• The characters may not be in the measurement region. Check to see if the measurement region is set correctly.
• The specified character format may not agree with the format of the read characters. Check the character format.

Reading a Variable Length Character String

Set the reading mode in the measurement parameters to [Variable]. The character format should be the same
as the maximum character string length format.
122
Reading and Verifying Character Strings
Setting
−2: Not measured,
0: Judgement is OK,
−1: Judgement is NG,
−16: Measurement timeout error,
−17: Format not entered error
0 to 100
0 to 100
0 to 32
0 to 32
0 to 32
0 to 32
0 to 100
0 to 100
Description
This is the judgement result.
This is the lowest similarity of the read characters.
This is the lowest stability of the read characters.
This is the number of characters that were read on line 1.
This is the number of characters that were read on line 2.
This is the number of characters that were read on line 3.
This is the number of characters that were read on line 4.
This is the similarity of read character N (N = 0 to 127).
This is the stability of read character N (N = 0 to 127).