6-1 Starting Operation
FQ2-S1
FQ2-S2
When test measurements and adjustments in Setup Mode have been finished, change to Run Mode and begin
actual measurements. In Run Mode, the Sensor operates stand-alone and outputs the measurement
judgement results on the I/O lines accordingly to the settings. If the Touch Finder or the PC Tool is connected
via network to the Sensor, the operation of the Sensor can be monitored in the following ways.
Run Mode Display
The present display
name.
Overall judgement
Measurement processing time
The time taken from when an
image is input until all
measurements have been
completed.
Inspection results can be
displayed in six formats, such
as in a list or as a trend graph.
p. 240
These buttons are
displayed both in Setup
and Run Mode.
p. 29
Moving to Run Mode
You can move from Setup Mode to Run Mode by using the following procedure.
1
Press [Run].
2
Press [Switch to Run mode.].
3
Press [Yes].
If you press [No], the setting will not be saved and
you will move to Run Mode.
238
Starting Operation
FQ2-S3
FQ2-S4
FQ2-CH
Selected inspection item
Connected
Sensor name
Currently selected
scene number,
scene name
Sub-menu
Used to select the
detection information to
display when more
than one detection
point is detected at the
same time for one item.
(FQ2-S series only)
Tool Button