Omron FQ2-S Series User Manual page 216

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Outputting the Calculation Results
The overall judgement (JG) of the calculations are reflected in the overall judgement of the inspection item. The
calculation result of each expression (J00 to J31) and calculation data (D00 to D31) can be output via Ethernet
or recorded as logging data.
Inspection items
(I0 to I31)
Data
Calculation
Process
Calculation
Expression 0
Expression 31
Ethernet output
Touch Finder (SD card)/Computer
214
Calculations and Judgements Using Inspection Item Data
judgement results
(OR0 to OR31)
• Data logging
• Judgement results
• Reference values
• Reference values
Upper and lower
limit judgement
Calculation
results (D00)
Upper and lower
limit judgement
Calculation
results (D31)
The results can be allocated to data 0 to 31 for Ethernet output.
The values of calculation results, calculation judgement results, and overall
judgement results can be recorded as logging data.
Logging p. 269
Individual
Calculation judgement
result (J00)
Overall judgement
result of calcula-
OR logic
tions (JG)
Calculation judgement
result (J31)
Overall judgement
result (OR)