In/Out Tab Page - Omron FQ2-S Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Menu command
Max Count
(Normal retry)
Interval
(Normal retry)
Brightness step or Shutter
speed step
(Exposure retry)
Increment count
(Exposure retry)
Decrement count
(Exposure retry)
*1
Refer to FQ2-S/CH Series User's Manual for Communications Settings (Cat. No. Z338).
*2
Not supported on the FQ2-CH Series.
*3
Not supported on the FQ2-S1/S2/S3 Series or FQ2-CH Series.
*4
Not supported on the FQ2-S1/S2/S3 Series.

In/Out Tab Page

Menu command
Statistical data
Image logging
Data log-
Condition
ging
Select data
Delete Log
OUT0
Control
to
signal
OUT2
Item
judge-
ment
Expres-
sion
judge-
ment
OR output
Output mode
Output delay
Output time
320
Menu Tables
Description
Sets the number of retries.
Sets the retry interval (msec).
Sets the exposure time step (msec).
Sets the increment count for the
brightness (shutter speed) step.
Sets the decrement count for the
brightness (shutter speed) step.
Description
Sets whether to record the number of
measurements and the number of NG
overall judgements.
Sets the parameter to log measurement
image data.
Sets the parameter to log measurement
data from inspection items.
You can select the parameters to log
from the parameters in the filter items,
position compensation items, inspection
items and expression that are set.
Resets the log data without turning OFF
the power supply.
Used to assign output signals to OUT0,
OUT1, and OUT2.
You can set the output conditions for the
OR signal and for output signals to which
judgements are assigned.
You can set the output mode for the OR
signal and for output signals to which
judgements are assigned.
When one-shot output mode is selected,
this parameter sets the delay from when
measurement processing is completed
until when the OR signal turns ON.
When one-shot output mode is selected,
this parameter sets the time that the OR
signal is ON.
Setting range
0 to 20, Default: 4
32 to 999, Default: 100
Brightness step:
1 to 20, Default 5
shutter speed step:
0.01 to 1.00 (Default: 0.30)
0 to 10, 2 (default)
0 to 10, 2 (default)
Setting range
ON (default) or OFF
All, Only NG, or None (default)
All, Only NG, or None (default)
Parameter names for the filter items,
position compensation items, inspection
items and expression that are set
---
OR (Total judgement (default assign-
ment: OUT0)), BUSY, ERROR (default
assignment: OUT2), READY (default
assignment: OUT1), RUN, STG
OR0 (Item0 judgement) to OR31 (Item31
judgement)
Exp.0 judgement to EXP. 31 judgement
OK: ON or NG: ON (default)
One-shot output, Level output (default)
0 to 1,000 ms (default: 0 ms)
1 to 1,000 ms (default: 5 ms)
Data
Refer-
ence
1
Scene
---*
Scene
Scene
Scene
Scene
Data
Refer-
ence
System
p. 275
System
p. 270,
p. 275
System
p. 270
System
p. 271
---
p. 276
1
System
---*
1
System
---*
1
System
---*
System
System
FQ2-S/CH User's Manual