OPTICS

2.2 1ST SCANNER/EXPOSURE LAMP REMOVAL

1. Turn off the main switch and unplug the power supply cord.
2. Remove the platen cover or DF.
3. Remove the exposure glass. (See Exposure Glass Removal.)
4. Remove the upper cover. (See Upper Cover Removal.)
5. Remove the rear cover. (See Rear Cover Removal.)
6. Move the 1st scanner 150 mm from the left scale, as shown by [A].
WARNING: To move the 1st scanner, pull the scanner belt. Do not apply
force to the scanner directly.
7. Remove the 1st scanner [B] (2 screws [C], white cable clamp [E] and 1
connector [D]).
NOTE: The 1st scanner contains the exposure lamp.
A219
CÓPIA NÃO CONTROLADA
[A]
A219R508.wmf
[B]
6-6
CÓPIA NÃO CONTROLADA
Rev. 8/29/97
[C]
[D]
[E]