2.11 ADS SENSOR REPLACEMENT

1. Turn off the main switch and unplug the power supply cord.
2. Remove the exposure glass. (See Exposure Lamp Removal.)
3. Remove the ADS sensor [A] and cover [B] as an ass'y (1 screw and 1
connector).
4. Replace the ADS sensor [A] (1 screw).
5. Reassemble.
6. Perform the ADS reference voltage adjustment. (See ADS Adjustment.)
SM
CÓPIA NÃO CONTROLADA
[B]
[A]
6-17
CÓPIA NÃO CONTROLADA
OPTICS
A219R566.wmf