Service Call Conditions - Ricoh A219 Service Manual

Table of Contents

Advertisement

2. SERVICE CALL CONDITIONS

NOTE: 1) E-codes are displayed in the copy counter. The "E" and the "code
number" are displayed alternatively.
2) To clear the service call condition, turn the main switch off and on.
3) When a fusing service call conditions occurs (example E52) , for
safety reasons they cannot be cleared by turning the main switch
off/on. The following procedure must be performed to clear these
service call conditions.
1. After repairing the machine, turn on the main switch.
2. Enter SP mode 97.
3. Turn the main switch off and on.
CODE #11 — EXPOSURE LAMP ERROR 1
- Definition -
The feedback signal becomes higher than 4.2 volts (rms) for 1.0
second when the exposure lamp is on.
The feedback signal becomes higher than 1.0 volt (rms) for 1.0
second when the exposure lamp is off.
- Possible Causes -
Triac short circuit
Exposure lamp open
Thermofuse open
CODE #12 — EXPOSURE LAMP ERROR 2
- Definition -
The feedback signal falls below 0.5 volt (rms) for 1.0 second when the
exposure lamp is on.
The exposure lamp stays on for longer than 25 seconds.
- Possible Causes -
Defective ac drive/dc power supply board
Defective main control board
Defective power supply circuit
SM