Exposure Lamp Voltage Control - Ricoh FT4220 Service Training Manual

Table of Contents

Advertisement

3.8 EXPOSURE LAMP VOLTAGE CONTROL

The main board controls the exposure lamp voltage through the ac drive
board. The exposure lamp voltage is based on the base lamp voltage and
various correction factors. The exposure lamp data setting determines the
base lamp voltage. The following table gives the approximate lamp voltage
for each data setting.
Exposure Lamp Data/Voltage Reference Table (SP48)
Exposure lamp voltage
Exposure
lamp data
115V
machine
100
57.1
101
57.6
102
58.2
103
58.8
104
59.3
105
59.9
106
60.5
107
61.1
108
61.6
109
62.2
110
62.8
111
63.3
112
63.9
113
64.5
114
65.0
115
65.6
116
66.2
117
66.8
118
67.3
119
67.9
120
68.5
121
69.0
122
69.6
123
70.2
124
70.8
125
71.3
NOTE: Exposure lamp rating: 115 V machine: 97 V/280 W
Default data value: 126
FT4220/4222
(standard)
220/230/240V
machine
105.9
106.9
108.0
109.1
110.1
111.2
112.2
113.3
114.4
115.4
116.5
117.5
118.6
119.6
120.7
121.8
122.8
123.9
124.9
126.0
127.1
128.1
129.2
130.2
131.3
132.4
220/230/240 V machine: 180 V/310 W
2-18
Exposure lamp voltage
Exposure
lamp data
115V
machine
126
71.9
127
72.5
128
73.0
129
73.6
130
74.2
131
74.7
132
75.3
133
75.9
134
76.5
135
77.0
136
77.6
137
78.2
138
78.7
139
79.3
140
79.9
141
80.5
142
81.0
143
81.6
144
82.2
145
82.7
146
83.3
147
83.9
148
84.4
149
85.0
150
85.6
(standard)
220/230/240V
machine
133.4
134.5
135.5
136.6
137.6
138.7
139.8
140.8
141.9
142.9
144.0
145.1
146.1
147.2
148.2
149.3
150.4
151.4
152.5
153.5
154.6
155.6
156.7
157.8
158.8
STM