3.8 AGITATOR REPLACEMENT

1. Open the front cover.
2. Remove the imaging unit. (See Imaging Unit Removal.)
3. Set the imaging unit on a large sheet of paper.
4. Remove the charge corona unit from the imaging unit. (See the charge
corona unit removal procedures.)
5. Empty all the developer onto the paper, making sure that no developer
remains on the development roller or in the unit.
6. Remove the cleaning blade and drum from the imaging unit. (See
cleaning blade, and drum removal procedures.)
7. Remove the toner recycling cover from the imaging unit. (See Toner
Recycling Belt Removal.)
8. Remove the upper case [A] (2 screws) from the imaging unit.
NOTE: When removing the upper case, do not lose the idle gear [B].
9. Remove and replace the agitators [C].
NOTE: 1) Make sure that agitators are positioned correctly, as shown [D].
2) When installing the new agitator, install a new bearing or apply
CPL501 evenly onto the old bearing.
SM
CÓPIA NÃO CONTROLADA
[B]
[C]
6-25
CÓPIA NÃO CONTROLADA
AROUND THE DRUM
[D]
[A]
A219R525.wmf