2.9 3RD MIRROR REPLACEMENT

[C]
1. Turn off the main switch and unplug the power supply cord.
2. Remove the upper cover. (See Upper Cover Removal.)
3. Move the 1st scanner two thirds of the way from the left scale, as shown.
WARNING: To move the 1st scanner, pull the scanner belt. Do not apply
force to the scanner directly.
4. Remove the bracket [A] (1 screw).
5. Remove the 2nd scanner [B], as shown (4 screws, 1 connector).
WARNING: 1) When removing the 2nd scanner, do not bend the bracket.
2) When reinstalling the 2nd scanner, thread the harness around
the pulley.
6. Replace the 3rd mirror [C] in the same way as the 2nd mirror.
NOTE: Make sure that the reflecting surface [D] faces the lens.
A219
CÓPIA NÃO CONTROLADA
A219R507.wmf
6-14
CÓPIA NÃO CONTROLADA
[B]
[A]
[D]