Basic Settings And Service Procedures; Access To The Test Mode (With Program Switch S9, Position 1) - Kärcher BR 100 R Service Manual

Table of Contents

Advertisement

Basic settings and service procedures

5.1.1 Access to the test mode
(with program switch S9, position 1)
Requirements
- Unit switched off
- Program switch (S9) in Pos 1 (Drive)
- Key switch (SO) in „O" position
Main relay (K1)
switches off
Error display
?
Display
shutdown soon
Switch off key switch (SO)
Display
Battery:
Water/C:
Note:
- If the rotary pulse generator is turned in an anti-clockwise direction the cursor acts in the opposite direction, i.e. the menu is
called up from the last to the first parameter. The last saved cursor can be called up again after quitting the menu, e.g. by
switching back to the standard display (battery display).
- Switch off the key switch (S0) to quit test mode
Page 78 / 171
no
yes
Error display
E....F
E....F
Control panel switches
KEH:
Sweeping operation
USR:
User (1 &2)
CD:
Chemical metering
Work: Working light
Rund: Beacon light
- Hold i-button inch function
- Switch on key switch (SO)
BR 100/250R
no
Display
yes
Main relay (K1)
no
>10s
yes
Battery voltage
24.1 = 2.0V/Z
Program selector
Switch 1-8
(S6)
KEH:0
(S7)
Work:0
(S8)
I_Drive motor:
(S4)
Travel direction
Switch -1
(S5)
Seat switch=
Accelerator=
Temperature drive
electronics:
I_brush/roller:
I_Suction motor:
Temp. cleaning
electronics 25°C
Temp. lift motor
Electronics 36°C
I_Main brush
I_Broom
I_Sweep fan
Temp. sweep
electronics :18°C
Temp. lift electronics
sweep unit
BR/BD 100/250 R BP / RI
and
Display
Self-test
Self-test
o.k.?
is connected
Display
Set TEST
MODE?
Display
1
USR:0 CD:0
Rund:0
0A
1
0,3V
33°C
0A
0A
0A
0A
0A
:28°C
Service Manual 08.2007