Significant Errors (Drive Module A2) - Kärcher BR 100 R Service Manual

Table of Contents

Advertisement

BR/BD 100/250 R BP / RI
6.3 Error memory

6.3.3 Significant errors (Drive module A2)

x
y
Description
Error
of module
number
0
Short circuit drive
motor (M1)
Hardware has detected
a dangerous current
increase.
1
Power supply is not
between 14V...50V /
Missing load circuit
supply.
2
Excess module tempe-
rature /
Temperature in load cir-
cuit stage exceeded the
approved value or ambi-
ent temperature is too
high.
3
Unacceptable accelera-
tor value /
Accelerator voltage is
outside the calibrated
range.
4
Overload of drive motor
(M1)
The programmed permit-
ted drive motor current
has exceeded the pro-
grammed permitted time
(overheating!)
Service Manual 08.2007
Brief description/
Error description
Synonymous
Run time
error
F1/131
– Short-circuiting drive motor (M1).
– Short circuit in motor cabling.
– Defect in power stage of the drive
motor.
F1/121
– Main relay coil (K1) is open.
– Fuse in module supply line
burned through.
– Cable break of the +-module
supply.
– Download electronic unit is
defective.
User
– Blocked drive motor (M1).
messages
– Overload on steep ramps.
– Cooling fan is defective.
– Cooling vents are plugged.
F1/162
– New accelerator pedal is not ca-
librated.
– No acceleration balance perfor-
med for new drive module (A2).
User
– Blocked motor (M1), i.e. due to
messages
magnet brake (Y1).
– Overload on steep ramps.
Troubleshooting
Potential causes
Page 147 / 171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents