Manufacture Settings - Module Parameters - Kärcher BR 100 R Service Manual

Table of Contents

Advertisement

Basic settings and service procedures
5.3 Setup menu
5.3.5
Module parameter manufacture settings
Head CPU version:
Drive module version:
Setup valid for:
Clean module version:
Lift module version:
Accessory module version:
Version of this parameter list:
Last amendment made on:
Parameter setup distributed to documentation/service on:
PARAMETER-SETUP, sequence and factory settings BR 100/250R(I) - State 2005/05/20
Module
Parameter presentation in
display
Language
selection: 0
0=German 1=Engl
Machine model:
BR 100/250 R
Beacon light when
reversing 0
Standby time:
30 min
Discharge voltage
32.4 v= 1.80 V/Z
Reset voltage
37.8 v= 2.10 V/Z
Minimum brush
pressure:
40A
System parameter
Lift mot. Brush 1
(head CPU)
0=ES; 1=Block
Filter vibration
time pre.sweeping:
15 s
Filter pause time
pre-sweeping:
120 s
Sweeper after run
time after stop:
3 s
Sweeper fan after
run time from
stop: 5 s
Warning messages?
0=yes; 1=no: 0
Chemical metering
On=1; Off=0: 0
B hrs:
0h00m
Load Backup?: 0
Max speed
forwards: 6.0 km/h
Max speed
backwards: 3.5 km/h
Approach ramp: 2
Braking ramp: 2
Max. motor current:
Max. braking
Driving module
current:
Overload limit:
Gas potentiometer
type:
1
Gas potentiometer
supply 8.0V
Motor constant:
0.045 m/(Vs)
Clean module (1)
Clone 1: control
of the scrubbing
brush and
vacuuming
Available in:
Basic unit
Basic unit + side
brush
Basic unit + pre-
sweeper
Page 100 / 171
from 1.2
up to 1.2
from 1.2
up to 1.0
up to 1.0
2
20.05.2005
21.05.2005
Factory setting
min:step:max
0
0.1
BR 100/250 R
BR 100/250 R
BD 100/250 R
BR 100/250 RI
BD 100/250 RI
0
0.1
30 min
10min:10min:240min Time after which an inactive machine switches
1.80 V/Z
1.65:0.01:1.95 V/Z
2.10 V/Z
2.10:0.01:2.20 V/Z
40A
20A:10A:50A
1
0.1
15s
5s:5s:120s
120s
15s:15s:600s
3s
0s:1s:5s +)
5s
0s:1s:20s +)
0
0.1
0
0.1
0
0.1
6 km/h**)
2.0km/h:0.5km/h:
9km/h
3.5 km/h**)
2.0km/h:0.5km/h:
9km/h
2
1:1:5
2
1:1:5
125A in basic unit
20A:5A:180A
180A in basic unit
125A
with pre-sweeper
125A in basic unit
20A:5A:180A
180A in basic unit
with pre-sweeper
125A
70A in basic unit
10A:5A:120A
120A in basic unit
70A
with pre-sweeper
1
0.1
8.0V
3.0V:0.1V:15.0V
0.045m/(Vs)**)
0.01:0.005:
0.255 m/(Vs)
BR/BD 100/250 R BP / RI
Notes
Language for Display texts, for the time being only
German and English aviable.
Selection of model for correct details in
information menu of the display.
If activated automatically switches on beacon light
for reversing.
itself off (only key-operated switch on)
Voltage at which cleaning stops. Can only by
driven and possibly lighting switched on.
Minimum voltage after battery charge in order to
beable to clean.
Start point for brush current contriller at minimum
brush pressure setting (1 bar in the display)
Option 1: Lift motor for brush works without limit
(end position) switch.
Duration of filter cleaning.
Fan running time between consecutive filter
cleaning operations
Time during which the sweeper still runs when
the machine at a standstill before the main brush,
side brush and fan switch off and the brush head is
raised.
Length of time during which sweeper suction fan
still runs when machine at a standstill before it
switches off
Option 1: Warning messages are generally hidden
in the display.
Option 1: Activates the hose pump control for
cleaning agent metering.
Option 1: Reload the backed up operating hours
from the cleaning module in the head CPU.
Maximum forwards travel speed during transport
Maximum reverse speed (this also replaces the
working speed).
Acceleration rate of the drive motor at full throttle.
Braking rate of the drive motor when accelerator
raised.
Maximum current to which the drive motor is
limited in motor mode during blockage.
Maximum current to which the drive motor is
limited during braking.
If the current exceeds this value a time counter is
activated. if the current falls back under this limit
the time counter is switched off again.
Specifies whether accelerator pedal used with or
without micro switch.
Accelerator pedal supply voltage.
Speed constant of the drive motor for calibration of
the speed controller.
CANNOT BE ADJUSTED!
Service Manual 08.2007
Order
Service
Development
access
access
1
X
2
X
3
X
4
X
5
X
6
X
7
X
8
X
9
X
Display only
for RI
versions
10
X
Display only
for RI
versions
11
X
Display only
for RI
versions
12
X
Display only
for RI
versions
13
X
14
X
15
X
1
X
2
X
3
X
#)
4
X
##)
5
X
6
X
7
X
8
X
9
X
10
X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents