Access To The Test Mode (With Program Switch S9, Position 2) - Kärcher BR 100 R Service Manual

Table of Contents

Advertisement

BR/BD 100/250 R BP / RI
5.1.2 Access to the test mode
(with program switch S9, position 2)
Requirements
- Unit switched off
- Program switch (S9) in Pos 2 (wet scrubbing with vacuuming)
- Key switch (SO) in „O" position
Main relay (K1)
switches off
Error display
?
Display
shutdown soon
Switch off key switch (SO)
Display
Battery:
Water/C:
Requirements:
The metering cycle must first be released in the setup
menu "Parameter menu system parameters"
with 1. Only then is the test cycle available
The test cycle is started and stopped with the i-Button (inch function).
The following units are controlled during the metering cycle.
- Open ball valve
- Water pump is switched on
- Metering pump receives nominal values
5/10/15/20/25/30% each step is automatically
active for 10s.
Note:
- If the rotary pulse generator is turned in an anti-clockwise direction the cursor acts in the opposite direction, i.e. the menu is
called up from the last to the first parameter. The last saved cursor can be called up again after quitting the menu, e.g. by
switching back to the standard display (battery display).
- Switch off the key switch (S0) to quit test mode
Service Manual 08.2007
no
yes
Error display
E....F
E....F
In this menu item you
can switch off all active
drives simultaneously
using the I-button inch
function.
On-off function or
open/closed See 5.1.2.1
Chemical metering On=1; Off=0 1
Basic settings and service procedures
- Hold i-button inch function
- Switch on key switch (SO)
BR 100/250R
no
Display
yes
Main relay (K1)
no
>10s
yes
Display
Switch off all drives
Brush/roller
Suction motor
Water pump
Open/close ball valve
Start metering cycle
and
Display
Self-test
Self-test
o.k.?
is connected
Display
Set TEST
MODE?
on/off
on/off
on/off
(O)
5
Page 79 / 171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents