CHAPTER 5 IMAGE FORMATION SYSTEM

7.2 Developing Assembly

7.2.1 Removing the Developing Assembly
1) Remove the left cover.
2) Open the front cover, and shift down the
developing assembly locking lever [1].
While pushing on the protrusion of the
toner cartridge, turn the grip fully
clockwise, and pull out the toner car-
tridge [2].
3) Turn the developing assembly locking
lever [3] clock wise to unlock.
4) Take out the drum unit (7.1.1 in Chapter
5)
5) Remove the multifeeder tray. (5.2.1 in
Chapter 6)
6) Remove the two screws [4], and detach
the shaft guide [5].
7) Holding the grips [6], slowly pull out
the developing assembly [7].
5-18
COPYRIGHT© 22002 CANON INC.
1
[3]
[2]
F05-702-01
[5]
F05-702-02
[6]
F05-702-03
2000
CANON iR1600/iR2000 REV.1 JAN. 2002
2
[1]
[4]
[7]