JUNOS Software with Enhanced Services Hardware Guide
4.
5.
Figure 52: Connecting DC Power to the J2350 Services Router
88
Connecting Power
overtighten. Apply between 8 lb-in. (0.9 Nm) and 9 lb-in. (1.02 Nm) of torque
to the screw.
Using the other removed screw, secure the negative (–) DC source power
f.
cable lug to the
48 VDC
overtighten. Apply between 8 lb-in. (0.9 Nm) and 9 lb-in. (1.02 Nm) of torque
to the screw.
Dress the power cables appropriately.
g.
Replace the clear plastic cover over the terminal block.
h.
Verify that the power cables do not block access to router components or drape
where people can trip on them.
On J2320 and J2350 routers, use the power cable tie as follows to relieve strain
on the cable (see Figure 52 on page 88 ):
Wrap the loose end of the tie around the cable, and insert it into the opening
a.
on the tie.
Pull the end to tighten the tie.
b.
To release the tie from the cable, press down the tab on the tie and loosen it.
terminal. Tighten the screw until snug. Do not