Traverse Function (Pr. 592 To Pr. 597) - Mitsubishi Electric FR-A700 Instruction Manual

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Special operation
6.24.7

Traverse function (Pr. 592 to Pr. 597)

Traverse operation which varies the amplitude of the frequency in a constant cycle can be per-
formed. This function of the is designed specifically for use in yarn-winding applications in the
textile industry.
Pr. No. Name
Traverse function
592
selection
Maximum amplitude
593
amount
Amplitude
594
compensation amount
during deceleration
Amplitude
595
compensation amount
during acceleration
Amplitude
596
acceleration time
Amplitude
597
deceleration time
When "1" or "2" is set in Pr. 592 "Traverse function selection", turning on the traverse operation
signal (X37) makes the traverse function valid.
Set "37" in any of Pr. 178 to Pr. 189 "Input terminal function selection" and assign the X37 signal
to the external terminal. When the X37 signal is not assigned to the input terminal, the traverse
function is always valid (X37-ON).
STF (STR)
Fig. 6-261: Traverse function
6 - 520
Initial
Setting
Description
Value
Range
0
Traverse function invalid
Traverse function is valid only in the
1
0
external operation mode
Traverse function is valid independ-
2
ently of operation mode
Amplitude amount during traverse
10%
0–25%
operation
Compensation amount at the time of
amplitude inversion (acceleration →
10%
0–50%
deceleration)
Compensation amount during ampli-
10%
0–50%
tude inversion operation
(deceleration → acceleration)
Acceleration time during traverse
5s
0.1–3600s
operation
Deceleration time during traverse
5s
0.1–3600s
operation
Output
frequency
ON
X37
Traverse operation
ON
Parameter
Parameters referred to
1
Maximum
frequency
2
Minimum
frequency
7
Acceleration time
8
Deceleration time
29
Acceleration/
deceleration
pattern selection
178–189
Input terminal
function selection
f0: set frequency
f1: amplitude amount from
the set frequency
(f0 × Pr. 593/100)
f2: compensation amount
at transition from
acceleration to
deceleration
(f1 × Pr. 594/100)
f3: compensation amount
at transition from
deceleration to
acceleration
(f1 × Pr. 595/100)
t1: time from acceleration
during traverse
Time [s]
operation
(time from (f0 + f1)
to (f0 − f1) (Pr. 597)
t2: time from deceleration
during traverse
operation
(time from (f0 − f1)
to (f0 + f1) (Pr. 596)
Refer to
Section
6.8.1
6.8.1
6.11.1
6.11.1
6.11.3
6.14.1
I001252E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents