Mitsubishi Electric FR-A700 Instruction Manual page 182

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter overview
Parameter
Func-
Name
tion
3
Base frequency
Base frequency voltage
19
Second V/f (base
47
frequency)
Third V/f (base
113
frequency)
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
24
Multi-speed setting
4 speed to 7 speed
27
232
Multi-speed setting
8 speed to 15 speed
239
Tab. 6-1:
Parameter overview (2)
6 - 2
Incre-
Initial
Setting
ments
Value
Range
0.01Hz
50Hz
0–400Hz
0–1000V
0.1V
8888
8888
9999
0–400Hz
0.01Hz
9999
9999
0–400Hz
0.01Hz
9999
9999
0.01Hz
50Hz
0–400Hz
0.01Hz
30Hz
0–400Hz
0.01Hz
10Hz
0–400Hz
0–400Hz/
0.01Hz
9999
9999
0–400Hz/
0.01Hz
9999
9999
Description
Set the frequency when the motor
rated torque is generated. (50Hz/
60Hz)
Maximum inverter output voltage
95% of power supply voltage
Same as power supply voltage
Set the base frequency when the
RT signal is on.
Second V/f is invalid.
Set the base frequency when the
X9 signal is on.
Third V/f is invalid.
Set frequency when the RH signal
is on.
Set frequency when the RM signal
is on.
Set frequency when the RL signal
is on.
Frequency from 4 speed to 15
speed can be set according to the
combination of the RH, RM, RL
and REX signals.
9999: not selected
Parameter
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled