Mitsubishi Electric FR-A700 Instruction Manual page 479

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
Setting
Terminal Function
Source
Sink
Logic
Logic
7
107
RBP
8
108
THP
10
110
PU
11
111
RY
12
112
Y12
13
113
Y13
14
114
FDN
15
115
FUP
16
116
RL
17
MC1
18
MC2
19
MC3
20
120
BOF
25
125
FAN
26
126
FIN
27
127
ORA
28
128
ORM
30
130
Y30
31
131
Y31
32
132
Y32
Tab. 6-86:
Output terminal function assignment (2)
FR-A700 EC
Regenerative brake prealarm
Electronic thermal relay function
prealarm
PU operation mode
Inverter operation ready
Output current detection
Zero current detection
PID lower limit
PID upper limit
PID forward/reverse rotation
output
Commercial power-supply
switchover MC1
Commercial power-supply
switchover MC2
Commercial power-supply
switchover MC3
Brake opening request
Fan fault output
Heatsink overheat prealarm
Orientation in-position
Orientation error
Forward rotation output
Reverse rotation output
Regenerative status output
Function assignment of external terminals
Operation
Output when 85% of the
regenerative brake duty set in
Pr. 70 is reached.
Output when the electronic
thermal relay function cumu-
lative value reaches 85%.
(Electronic thermal relay
function protection (E.THT/
E.THM) activates, when the
value reached 100%.)
Output when the PU opera-
tion mode is selected.
Output when the inverter can
be started by switching the
start signal on or while it is
running.
Output when the output cur-
rent is higher than the Pr. 150
setting for longer than the
time set in Pr. 151.
Output when the output
power is lower than the Pr.
152 setting for longer than the
time set in Pr. 153.
Output when the feedback
value falls below the lower
limit of PID control.
Output when the feedback
value rises above the upper
limit of PID control.
Output when forward rotation
is performed in PID control.
Used when the commercial
power supply-inverter switch-
over function is used.
Output to open the brake
when the brake sequence
function is selected.
Output at the time of a fan
fault.
Output when the heatsink
temperature reaches about
85% of the heatsink overheat
protection providing
temperature.
When orientation is valid
Output when the motor is run-
ning in forward direction.
Output when the motor is run-
ning in reverse direction.
Output in the regenerative
status under vector control
operation.
Related Parame-
Refer to
ters
Page
Pr. 70
6-247
Pr. 9
6-216
Pr. 79
6-415
6-303
Pr. 150, Pr. 151
6-312
Pr. 152, Pr. 153
6-312
Pr. 127–Pr. 134,
6-488
Pr. 575–Pr. 577
Pr. 135–Pr. 139,
6-502
Pr. 159
Pr. 278–Pr. 285,
6-261
Pr. 292
Pr. 244
6-526
7-14
Pr. 350–Pr. 366,
Pr. 369, Pr. 393,
6-266
Pr. 396–Pr. 399
6-306
6 - 299

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents