Selection of operation mode and operation location
Switching of command source by external terminal (X67)
In network operation mode, the command source switching signal (X67) can be used to switch
the operation command source and speed command source. This signal can be utilized to con-
trol the signal input from both the external terminal and communication.
Set "67" to any of Pr. 178 to Pr. 189 to assign the X67 signal to the external terminal.
When the X67 signal is off, the operation command source and speed command source are
external.
No signal assignment
Tab. 6-129: Switching of command source by the signal X67
NOTES
The ON/OFF state of the X67 signal is reflected only during a stop. It is reflected after a stop
when the terminal is switched during operation.
When the X67 signal is off, a reset via communication is disabled.
Changing the terminal assignment using Pr. 178 to Pr. 189 "Input terminal function selec-
tion" may affect the other functions. Please make setting after confirming the function of
each terminal.
6 - 436
X67 Signal State
ON
OFF
Operation Command Source
According to Pr. 338
Operation is valid only from external terminal signal.
Parameter
Speed Command Source
According to Pr. 339