Simple mode parameter list
If the conditions below are not satisfied, malfunction such as insufficient torque and uneven ro-
tation may occur.
● The motor capacity should be equal to or one rank lower than the inverter capacity.
● Motor to be used is either Mitsubishi standard motor with encoder, high efficiency motor
(SF-JR, SF-HR two-pole, four-pole, six-pole 0.4kW or more) or Mitsubishi constant-torque
motor (SF-JRCA, SF-HRCA four-pole 0.4kW to 55kW) or vector control dedicated motor
(SF-V5RU). When using a motor other than the above (other manufacturer's motor), perform
offline auto tuning without fail.
● Single-motor operation (one motor run by one inverter) should be performed.
● Wiring length from inverter to motor should be within 30m. (Perform offline auto tuning in
the state where wiring work is performed when the wiring length exceeds 30m.)
NOTE
Changing the terminal assignment using Pr. 178 to Pr. 189 "Input terminal function selec-
tion" may affect the other functions. Make setting after confirming the function of each termi-
nal.
b
CAUTION:
Do not perform vector control with an output filter connected.
5 - 20