Parameter
Refer to the following table and set Pr. 73 and Pr. 267. The half-tone screened areas indicate
the main speed setting. The other inputs are used for compensation.
Pr. 73
0
1
(initial
value)
2
3
4
5
6
7
10
11
12
13
14
15
16
17
0
1
2
3
4
5
6
7
10
11
12
13
14
15
16
17
Tab. 6-105: Setting of parameter 73 and 267
Indicates that a frequency command signal of negative polarity is not accepted.
FR-A700 EC
Frequency/torque setting by analog input (terminals 1, 2 and 4)
AU
Terminal 2
Terminal 1
Signal
Input
Input
0 to ±10V
0 to 10V
0 to ±10V
0 to 5V
0 to ±5V
0 to 10V
0 to ±5V
0 to 5V
0 to ±10V
0 to 10V
0 to ±5V
0 to 5V
0 to ±10V
0/4 to 20mA
0 to ±5V
OFF
0/4 to 20mA
0 to ±10V
0 to 10V
0 to ±10V
0 to 5V
0 to ±5V
0 to 10V
0 to ±5V
0 to 5V
0 to ±10V
0 to 10V
0 to ±5V
0 to 5V
0 to ±10V
0/4 to20mA
0 to ±5V
0/4 to20 mA
0 to ±10V
0 to ±10V
0 to ±5V
0 to ±5V
0 to 10V
0 to 5V
0 to ±10V
0 to ±5V
ON
0 to ±10V
0 to ±10V
0 to ±5V
0 to ±5V
0 to 10V
0 to 5V
0 to ±10V
0 to ±5V
Compensation Input
Terminal 4
Terminal and Compensa-
Input
tion Method
Terminal 1
Added compensation
Terminal 2
Override
Terminal 1
Added compensation
Terminal 2
Override
Terminal 1
Added compensation
Terminal 1
Added compensation
Terminal 2
Override
According to
Pr. 267 set-
ting:
0: 4 to 20mA
(initial value)
Terminal 1
1: 0 to 5V
Added compensation
2: 0 to 10V
Terminal 2
Override
Terminal 1
Added compensation
Polarity Reversible
No
Yes
No
Yes