Parameter
Parameter
Func-
Name
tion
7
Acceleration time
8
Deceleration time
Acceleration/
deceleration reference
20
frequency
Acceleration/
deceleration time
21
increments
Second acceleration/
44
deceleration time
Second deceleration
45
time
Third acceleration/
110
deceleration time
Third deceleration time
111
Tab. 6-1:
Parameter overview (3)
FR-A700 EC
Incre-
Initial
Setting
ments
Value
Range
0.1/
0–3600/
5/15s *
0.01s
360s
0.1/
0–3600/
5/15s *
0.01s
360s
0.01Hz
50Hz
1–400Hz
0
1
0
1
0.1/
0–3600/
5s
0.01 s
360s
0–3600/
360s
0.1/
9999
0.01s
9999
0–3600/
0.1/
360s
9999
0.01s
9999
0–3600/
360s
0.1/
9999
0.01s
9999
Description
Set the motor acceleration time
* Initial values differ according to
the inverter capacity:
(00170 or less/00250 or more)
Set the motor deceleration time
* Initial values differ according to
the inverter capacity:
(00170 or less/00250 or more)
Set the frequency referenced as
acceleration/deceleration time. As
acceleration/deceleration time, set
the frequency change time from
stop to Pr. 20.
Increments:
0.1s
Increments and
Range:
setting range of
0–3600s
acceleration/
deceleration time
Increments:
setting can be
0.1s
changed.
Range:
0–360s
Set the acceleration/deceleration
time when the RT signal is on.
Set the deceleration time when the
RT signal is on.
Acceleration time = deceleration
time
Set the acceleration/deceleration
time when the X9 signal is on.
Function invalid
Set the deceleration time when the
X9 signal is on.
Acceleration time = deceleration
time
Parameter overview
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-195