Electromagnetic compatibility (EMC)
3.9.3

EMC filter

The inverter is equipped with a built-in EMC filter and zero-phase reactor. Effective for reduction
of air-propagated noise on the input side of the inverter. The EMC filter is factory-set to enable
(ON). To disable it, fit the EMC filter ON/OFF connector to the OFF position. The filter must be
deactivated when the inverter is used in networks with an isolated neutral (IT networks).
The input side zero-phase reactor, built-in the 01800 or less inverter, is always valid regardless
of on/off of the EMC filter on/off connector.
EMC filter OFF
00023 to 00126
Fig. 3-50: Built-in EMC filter
How to disconnect the connector
After confirming that the power supply is off, remove the front cover. (For the front cover
removal method, refer to section 2.2).
When disconnecting the connector, push the fixing tab and pull the connector straight without
pulling the cable or forcibly pulling the connector with the tab fixed. When installing the
connector, also engage the fixing tab securely.
If it is difficult to disconnect the connector, use a pair of long-nose pliers, etc.
Fig. 3-51: Activating the built-in EMC filter
NOTE
Fit the connector to either ON or OFF.
m
WARNING:
While power is on or when the inverter is running, do not open the front cover.
Otherwise you may get an electric shock.
3 - 64
00023 to 00126
EMC filter ON
EMC filter OFF
(initial setting)
00170, 00250
EMC filter
Disengage connector fixing tab
OF/OFF connector
(Side view)
00170, 00250
EMC filter ON
(initial setting)
00310, 00380
00470, 00620
Wiring
00310 to 12120
EMC filter OFF
EMC filter ON
(initial setting)
00770 to 12120
Connector
with/without
EMC filter
I001052E
With tab disengaged,
pull off connector straight.
I001053E