Page: 149
Service Guide OKIPAGE 24DX/24DXn
Chapter C Duplex Unit Maintenance
3.3.4 SOLENOID Assy
(1) Remove the Frame-Main (DUP) (See section 3.3.2).
(2) Release the lock to remove Two LEVER Sensor (F/R) (1) and two SPRING-Sensor (F/R) (2).
(3) Unplug the Connection Code-Wire (3) and remove Photo Sensor (4).
(4) Take away the SPRING-SL (5) and two screws (6) to remove SOLENOID Assy (7).