Page: 43
Service Guide OKIPAGE 24DX/24DXn
Chapter 3 Parts Replacement
3.3.13 Guide Assy - Eject
(1) Remove the lever back up release. [See 3.3.12(8)] (But the roller transfer/feeder unit front/plate-FG do not have
to be removed)
(2)
(2) Loosen 2 screws (1), unlock both side latches and remove the cover rear
. [See 3.3.6(5)]
(3)
(3) Unlock the latches on both sides of the guide assy-eject
and lift it out.