Service Guide OKIPAGE 24DX/24DXn
Chapter 2 Operation Description

2.5 Cover Open

When the stacker cover is opened, the cover open microswitch on the Power Supply Unit (High voltage) is
turned off to cut the supply of +30V to the high voltage power supply circuit. As a result, all high-voltage
outputs are interrupted. At the same time, the CVOPN signal is sent to the control board to notify it of the
off state of the microswitch, and the Main board performs the cover open processing.