3.1 Precautions for Parts Replacement

(1) Be starting parts replacement, remove the AC cable and interface cable.
(a) Remove the Ac cable in the following procedure:
i) Turn off ("o") the power switch of the printer.
ii) Disconnect the AC inlet plug of the AC cable from the AC receptacle.
iii) Disconnect the AC cable and interface cable from the printer.
(b) Reconnect the printer in the following procedures:
i) Connect the AC cable and interface cable to the printer.
ii) Connect the AC inlet plug to the AC receptacle.
iii) Turn on ("I") the power switch of the printer.
(2) Do not try disassembly as long as the printer is operating normally.
(3) Do not remove unnecessary parts: try to keep disassembly to a minimum.
(4) Use specified service tools.
(5) When disassembling, follow the determined sequence. Otherwise, parts may be damaged.
(6) Since screws, collars and other small parts are likely to be lost, they should temporarily be attached to
the original positions.
(7) When handling ICs such as microprocessors, ROM and RAM, and circuit boards, do not wear gloves
that are likely to generate static electricity.
(8) Do not place printed circuit boards directly on the equipment or floor.