Oki Data CONFIDENTIAL
4.2.24 Roller-feed, roller-pickup, frame Assy.-pickup,
and holder sensor Assy.
(1) Remove the roller Assy.-registration. (Refer to section 4.2.23)
(2) Remove the spring-pickup ① .
(3) Remove the two round-head screws (black) ② , disconnect the cable from the
clamp, and detach the cover Assy. hopping ③ .
②
③
45850101TH Rev.1
①
②
(4) Remove the roller-feed ④ and the roller-pickup ⑤ .
⑤
④
4. REPLACEMENT OF PARTS
4-46