logging facility-type

This command sets the facility type for remote logging of syslog messages.
Syntax
logging facility-type <type>
type ‐ A number that indicates the facility used by the syslog server to dispatch log messages 
to an appropriate service. Range: 16‐23
Default Setting
16
Command Mode
Global Configuration
Command Usage
The command specifies the facility type tag sent in syslog messages (refer to RFC 3164.) This 
type has no effect on the kind of messages reported by the access point. However, it may be 
used by the syslog server to sort messages or to store messages in the corresponding database.
Example
RoamAbout 3000#configure
Enter configuration commands, one per line. End with CTRL/Z
RoamAbout 3000(config)#logging facility 19
RoamAbout 3000(config)#