GBIC_SECURITY_CRYPT Messages

GBIC_SECURITY_CRYPT Messages
The Catalyst 3750-X, 3750-E, 3560-X, and 3560-E switches support SFP and 10-Gigabit Ethernet
Note
modules but do not support GBIC modules. Although the error message text refers to GBIC interfaces
and modules, the messages from the switches actually refer to the SFP and 10-Gigabit Ethernet module
interfaces and modules.
Error Message GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for
GBIC in port [chars]
Error Message GBIC_SECURITY_CRYPT-4-UNRECOGNIZED_VENDOR: GBIC in port [chars]
manufactured by an unrecognized vendor
Error Message GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port [chars] has bad
crc
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
2-38
The SFP module was identified as a Cisco SFP module, but the system could not verify
Explanation
its identity. [chars] is the port.
Ensure that the Cisco IOS software running on the switch supports the SFP
Recommended Action
module. You might need to upgrade your software. Otherwise, verify that the SFP module was
obtained from Cisco or from a supported vendor.
The SFP module was identified as a Cisco SFP module, but the switch could not match
Explanation
its manufacturer with one on the known list of Cisco SFP module vendors. [chars] is the port.
Ensure that the Cisco IOS software running on the switch supports the SFP
Recommended Action
module. You might need to upgrade your software.
The SFP module was identified as a Cisco SFP module, but it does not have a valid
Explanation
cyclic redundancy check (CRC) in the EEPROM data. [chars] is the port.
Ensure that the Cisco IOS software running on the switch supports the SFP
Recommended Action
module. You might need to upgrade your software. Even if the SFP module is unrecognized by the
switch, the SFP module might still operate properly but have limited functionality.