ILPOWER Messages
Error Message ILPOWER-5-IEEE-DISCONNECT: Interface [chars]: PD removed.
Explanation
being powered by an external AC power source. The switch is no longer providing power to the port.
[chars] is the interface.
Recommended Action
Error Message ILPOWER-5-ILPOWER_POWER_CDP_SHUT: Interface [chars]: inline power shut
Explanation
than the allocation power, the hardware interface limit, the user-configured maximum power, or the
available power on this switch. [chars] is the interface.
Recommended Action
Error Message ILPOWER-5-ILPOWER_POWER_DENY: Interface [chars]: inline power denied.
Explanation
the interface.
Recommended Action
Error Message ILPOWER-5-INVALID_IEEE_CLASS: Interface [chars]: has detected invalid
IEEE class: [dec] device. Power denied
Explanation
to the device. [chars] is the interface. [dec] is the IEEE class number.
Recommended Action
Error Message ILPOWER-5-LINKDOWN_DISCONNECT: Interface [chars]: Link down
disconnect.
Explanation
device is being powered by an external AC power source. The switch is no longer providing power
on the interface. [chars] is the interface.
Recommended Action
Error Message ILPOWER-5-POLICE_POWER_INVALID: Interface [chars]: invalid power
police [dec] milliwatts current [dec] mA voltage [dec] mV
Explanation
[dec] is the power policing limit (cutoff value in mW), the second [dec] is the power usage in mA,
and the third [dec] is the power usage in mV.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
2-48
The powered device is not connected to the switch, or the connected powered device is
No action is required.
Inline power is shut down because CDP consumption power on this PoE port is greater
No action is required.
There is not enough power remaining in the switch to supply to the PoE port. [chars] is
Connect the powered device to an external AC power source.
The powered device has an invalid IEEE class so that the switch is not providing power
No action is required.
The powered device is no longer connected to the switch, or the connected powered
No action is required.
The power policing current or voltage value is invalid. [chars] is the interface. The first
Copy the message exactly as it appears on the console or in the system log.
Chapter 2
Message and Recovery Procedures